Application & Quality
Processing, Rework & Material Care
Tack, reuse and service life, electrical insulation, flammability, mixing and storage, and the certifications behind the data.
01
What does natural tack mean?
The natural tack of silicone pads provides light surface adhesion that helps hold the material in place during assembly. MWK thermal pad options include single-sided and double-sided tack — confirm the available surface treatment for the selected grade.
02
Can thermal pads be reused?
Your engineering team should assess the material condition and the interface before deciding whether a pad can be reused.
03
What is the expected service life?
Service life depends on the product formulation, interface design and operating environment. Confirm the expected service life and qualification data for the selected MWK grade against its current technical data sheet.
04
Will hardness change after heating?
Hardness stability depends on the material formulation and thermal exposure. Confirm the operating-temperature range and the post-aging hardness data for the specific MWK grade before use.
05
Are silicone thermal pads electrically insulating?
MWK silicone thermal pads are designed to provide electrical insulation. Check the breakdown voltage, specimen thickness and volume resistivity of the selected grade in its technical data sheet.
06
What flammability ratings are listed?
MWK reports UL certification for its products. Confirm the applicable UL 94 flammability rating and certificate for the exact product and grade.
07
How are volatile substances and oil bleed addressed?
Volatilization, outgassing and oil bleed are formulation- and process-dependent properties. Evaluate them under representative temperature, pressure and vacuum conditions using the applicable test methods.
08
How should two-part liquid gap fillers be mixed and stored?
Mix the two components within ±5% of the specified ratio — light-coloured streaks or marble-like patterns indicate insufficient mixing. After A and B meet in the mixing head, viscosity begins to rise within about 5 minutes, the surface dries at about 10 minutes, and an elastic cured state develops over roughly 30 minutes to 3 hours. Store in the original sealed container at or below 25 °C and 50% relative humidity unless the data sheet states otherwise, and do not use expired material.
09
Can cured liquid gap filler be used as a structural adhesive?
No. Cured liquid gap filler may have low natural tack and keep contact with adjacent components through temperature cycling, but it is not a structural adhesive and must not be used to secure a heat sink.
10
How are one-part materials applied?
One-part materials can be applied by screen printing, offset printing or dispensing. Screen printing is a fast, low-cost way to apply a controlled quantity. These compounds do not require post-curing and are designed to hold wettability through thermal and power cycling.
11
What should I know about liquid gap filler handling?
Brief exposure above 25 °C during transportation is stated not to affect material properties. Expired thermal gel should not be used and cannot be re-certified. Rework may be possible depending on interface topography and area covered. After curing, liquid gap filler is specified for long-term operation from −40 °C to 150 °C, and its low natural tack keeps contact with adjacent components through temperature cycling without bonding structural parts.
12
Which certifications and compliance documents apply?
MWK reports ISO 9001 and ISO 14001 management-system certifications and UL certification for its products. Confirm product-specific restricted-substance declarations and compliance documents before design release.