Frequently Asked Questions

Practical answers on thermal interface materials — from selecting the right material and reading its data, to processing, rework, electrical behaviour and the quality certifications behind it.

Fundamentals

Thermal Interface Materials & Selection

Why TIMs are used, the common material families, how the numbers are tested, and the limits you should check.

01 Why use a thermal interface material?
A TIM fills the air gaps between two contact surfaces and conforms to rough or uneven mating surfaces. Because the material conducts heat more effectively than the air it displaces, it reduces interface thermal resistance and lowers the temperature at the device junction.
02 What types of TIM are commonly used?
Common types include thermal silicone pads, two-component gap fillers, thermal insulation sheets, one-component gap fillers, thermal potting compounds, thermal grease, graphite sheets, copper foil, aluminium foil and liquid metal. Other material families include phase-change materials, adhesives and thermal tapes.
03 What is the difference between thermal conductivity and thermal resistance?
Thermal conductivity describes a material’s inherent ability to conduct heat. Thermal resistance describes the opposition to heat flow through the material or interface under defined test conditions. Both properties matter — a highly conductive material may still perform poorly if it cannot make effective contact with the surfaces.
04 Which thermal conductivity test method is used?
MWK references ASTM D5470 for thermal conductivity and thermal resistance. Compare values only when the test method, specimen thickness, applied pressure and the other conditions are equivalent.
05 Can TIMs be used in every environment?
MWK quotes −45 °C to 200 °C as a general operating-temperature range for thermal interface materials; the specific range is defined by each product data sheet. MWK does not test its materials for liquid environments — validate compatibility, reliability and performance in the intended environment and avoid exposure to dust, dirt, grease and other contaminants.
06 Why are wettability and compliance important?
A material that wets the mating surfaces and conforms to interface irregularities fills gaps more effectively and reduces the thermal resistance associated with voids and poor contact.
Application & Quality

Processing, Rework & Material Care

Tack, reuse and service life, electrical insulation, flammability, mixing and storage, and the certifications behind the data.

01 What does natural tack mean?
The natural tack of silicone pads provides light surface adhesion that helps hold the material in place during assembly. MWK thermal pad options include single-sided and double-sided tack — confirm the available surface treatment for the selected grade.
02 Can thermal pads be reused?
Your engineering team should assess the material condition and the interface before deciding whether a pad can be reused.
03 What is the expected service life?
Service life depends on the product formulation, interface design and operating environment. Confirm the expected service life and qualification data for the selected MWK grade against its current technical data sheet.
04 Will hardness change after heating?
Hardness stability depends on the material formulation and thermal exposure. Confirm the operating-temperature range and the post-aging hardness data for the specific MWK grade before use.
05 Are silicone thermal pads electrically insulating?
MWK silicone thermal pads are designed to provide electrical insulation. Check the breakdown voltage, specimen thickness and volume resistivity of the selected grade in its technical data sheet.
06 What flammability ratings are listed?
MWK reports UL certification for its products. Confirm the applicable UL 94 flammability rating and certificate for the exact product and grade.
07 How are volatile substances and oil bleed addressed?
Volatilization, outgassing and oil bleed are formulation- and process-dependent properties. Evaluate them under representative temperature, pressure and vacuum conditions using the applicable test methods.
08 How should two-part liquid gap fillers be mixed and stored?
Mix the two components within ±5% of the specified ratio — light-coloured streaks or marble-like patterns indicate insufficient mixing. After A and B meet in the mixing head, viscosity begins to rise within about 5 minutes, the surface dries at about 10 minutes, and an elastic cured state develops over roughly 30 minutes to 3 hours. Store in the original sealed container at or below 25 °C and 50% relative humidity unless the data sheet states otherwise, and do not use expired material.
09 Can cured liquid gap filler be used as a structural adhesive?
No. Cured liquid gap filler may have low natural tack and keep contact with adjacent components through temperature cycling, but it is not a structural adhesive and must not be used to secure a heat sink.
10 How are one-part materials applied?
One-part materials can be applied by screen printing, offset printing or dispensing. Screen printing is a fast, low-cost way to apply a controlled quantity. These compounds do not require post-curing and are designed to hold wettability through thermal and power cycling.
11 What should I know about liquid gap filler handling?
Brief exposure above 25 °C during transportation is stated not to affect material properties. Expired thermal gel should not be used and cannot be re-certified. Rework may be possible depending on interface topography and area covered. After curing, liquid gap filler is specified for long-term operation from −40 °C to 150 °C, and its low natural tack keeps contact with adjacent components through temperature cycling without bonding structural parts.
12 Which certifications and compliance documents apply?
MWK reports ISO 9001 and ISO 14001 management-system certifications and UL certification for its products. Confirm product-specific restricted-substance declarations and compliance documents before design release.

Didn’t find your question? Our thermal engineers can review your interface, materials and process and point you to the right data sheet.

Contact our engineers

Not sure which material fits your heat path?

Send the heat load, gap and environmental class — our application engineers will recommend the material and format for that position.

Talk to engineering